The Go-Suppress Fire Tubing Detection System is an advanced automatic fire suppression solution engineered to detect and extinguish fires at their point of origin — before they spread. Powered by heat-sensitive polymer detection tubing, the system requires no external power supply, no manual activation, and no complex electronics to operate. When exposed to high temperatures, the tubing burst at the hottest point, instantly releasing a clean fire suppression agent directly onto the fire source. This localised, direct-release mechanism makes Go-Suppress ideal for vehicles, electrical panels, server racks, control cabinets, engine compartments, and other enclosed high-risk areas where traditional fire detection systems are too slow or too damaging.
Designed and distributed by Global Hi-Technologies Pte. Ltd. across the EMEA and APAC regions, Go-Suppress combines proven fire detection technology with a simple, cost-effective, and low-maintenance design.
Unlike conventional sprinkler or gaseous suppression systems that flood an entire zone, Go-Suppress releases its agent directly at the point of ignition. This localised response minimises collateral damage to surrounding equipment and assets — extinguishing fires before they spread.
Go-Suppress operates entirely on thermal and pneumatic principles — activating automatically without any external electrical power, control panel, or manual trigger. The heat-sensitive tube acts as a continuous linear detector along its entire installed length, eliminating blind spots and coverage gaps.
Go-Suppress is flexible, scalable, and cost-effective — providing reliable autonomous fire protection for vehicles, electrical infrastructure, server hardware, and industrial enclosures with minimal installation complexity and no ongoing power requirement.
Flexible polymer tubing installs easily in new or existing enclosures. With no regular testing cycles, no mechanical components to service, and no power requirements, Go-Suppress is one of the lowest-maintenance suppression options available.
Operate as a standalone system or integrate with existing security infrastructure, including alarm panels, buzzers, and external monitoring systems, tailored to your site requirements.
Built to perform where others can’t. From the extreme heat of an engine compartment to the controlled environment of a data center, our solutions are rated for -20°C to 80°C. Whether integrated into fleet vehicles or industrial electrical panels, this unit ensures high-performance stability in both mobile and fixed applications.
| Parameter | Specification |
|---|---|
| Tube Material | Heat-Sensitive Polymer Tube |
| Tube Diameter | 6 mm / 8 mm /10mm / 12mm / 18mm / 20mm /25mm / 32mm (Optional) |
| Cylinder Material | Carbon Steel / Stainless Steel |
| Mounting Type | Wall / Cabinet / Vehicle Mount |
| Parameter | Specification |
|---|---|
| Activation Temperature | 100°C – 170°C (Customisable) |
| Agent Type | Clean Agent / ABC Dry Chemical (Optional) |
| Tube Length | 1 m – 20 m (Customisable) |
| Response Time | Instant at activation temperature |
| Working Pressure | As per agent specification |
| Operating Temperature | -20°C to 80°C |
| Primary Applications | Engine compartments, Electrical panels, Server racks, Control cabinets, Vehicles |
| Parameter | Specification |
|---|---|
| Alarm Output | Optional Signal Output |
| Power Supply | Not Required (Stand-Alone System) |
| Integration | Compatible with Fire Alarm Systems |
Widely deployed in passenger vehicles, fleet trucks, buses, and specialist vehicles to protect engine compartments from fire caused by fuel leaks, overheating components, or electrical faults. Activates automatically before fire reaches the fuel tank or passenger cabin.
Tubing routed inside live panels provides round-the-clock protection without disrupting electrical operation. The clean agent option ensures no conductive residue is left on live components.
Provides localised fire suppression inside server racks and data centre cabinets, protecting hardware from both fire damage and the collateral damage caused by water-based suppression systems.
Autonomous fire protection for SCADA panels, PLC cabinets, and automated machinery enclosures in enclosed, hard-to-access spaces where conventional detection is slow to respond.
Tubing routed through machine enclosures and cutting zones provides suppression precisely at the origin point of fire risk from cutting fluids, hydraulic oils, and electrical components.
Standalone, power-free operation makes Go-Suppress ideal for engine rooms, generator compartments, and fuel storage areas on vessels and offshore platforms where electrical supply cannot be guaranteed.
Fire is extinguished at its source before it spreads — minimising asset loss, equipment damage, and operational downtime.
Fully autonomous thermal and pneumatic operation — works even during power outages or total electrical failures when protection matters most.
Safe for sensitive electronics — no post-discharge clean-up required, no equipment damage from the suppressant, minimal downtime after a suppression event.
Lower installation and operational cost than traditional suppression systems. Easy to install in existing enclosures without major infrastructure modification.
24/7 continuous monitoring with no standby power consumption or routine test cycles required — always on, always monitoring, always ready to respond.
Looking to protect vehicles, electrical infrastructure, server hardware, or industrial equipment from fire risk? Contact Global Hi-Technologies to discuss your specific application requirements, obtain system design recommendations, and request competitive pricing.